Medical World Company 

The Way To Secure Community Health 

Anesthsia Machine – Fuji Maximus

DESCRIPTION 

Developed to attend to the most diverse ventilation conditions, the new Fuji Maximus brings sophisticated ventilation resources to anesthesia with modes controlled by volume, pressure and spontaneous ones triggered by flow or pressure. For Neonatal to Bariatric patients with medium- and high-complexity elective surgery, such as Cardiology, Pediatric, Oncology and Gastroplasty, among others

 

TECHNICAL INFORMATION

Cabinet Description: Equipped with three drawers, with the upper drawer with dividers for drugs, table with a stainless steel cover, upper shelf to support monitors, trolleys equipped with locks on the front ones and transportation handle. The device also has the Ergo System® that allows one to rotate the equipment's upper module by up to 45º.

 

Cabinet Description: Equipped with three drawers, with the upper drawer with dividers for drugs, table with a stainless steel cover, upper shelf to support monitors, trolleys equipped with locks on the front ones and transportation handle. The device also has the Ergo System® that allows one to rotate the equipment's upper module by up to 45º.

Electronic Rotameter: For O2, N2O, Compressed Air, with 02 scales for each gas, one for Low Flows (10 to 1000 mL/min) and the other for High ones (1.5 to 10 L/min), and high intensity back light. Proportional flow servomatic that ensures a minimum 25% O2 concentration in the O2/N2O mixture, pressure servomatic that automatically cuts the N2O flow in the absence of O2 pressure, audiovisual low O2 pressure alarm, manometers to monitor gas sources (0 to 100 PSI) and incorporated pressure adjustment valves.

Electronic Ventilator: Micro processed for anesthesia, with a 20- to 2000-ml volume range that attends neonatal, pediatric, and adult patients. VCV, PCV, SIMV/V and SIMV/P® modes. Direct tidal volume, frequency, I/E ratio, plateau, maximum pressure and PEEP adjustments on the main screen. Triggering flow, triggering pressure, type of flow, support pressure and FiO2 calibration on the menu screen. Integrated monitoring with Pxt, Fxt, Vxt curves and VxP and FxV loops. Numerical values for exhaled volume, maximum pressure, average and plateau pressures, dynamic or static compliance, and FiO2 (optional).

Multi-agent Vaporizer: Micro processed to use the Halothane, Enflurane, Isoflurane and Sevoflurane agents, it has an electronic display with the concentrationtable.

versus the bubbling flow that dispenses the use of the slide rule and two rotameters for bubbling flow, with scales of 0 to 350 ml for low flows and 400 to 2200 ml for high flows.

Universal amber transparent bubbling chamber with a capacity for 100 ml of anesthetic agents and the unique MINI-PINOMATIC chamber exchange system with automatic identification of the agent in use.

SIVA® - Ventilator/Anesthesia Interface System: CO2 Absorber Filter integrated to the anesthesia ventilator and the continuous flow system (FGF). Alternating between mechanical and manual ventilation takes place through a bag-ventilator switch; the manual ventilation has a gradated pressure limit valve (APL) that ensures a reliable tidal flow that can be monitored through a mark on the bell. Autoclavable unidirectional inhalation and exhalation valves, canisters, and respiratory circuit.